Description
overviews
WSS series bimetallic thermometers with thermocouple (resistance) and temperature transmitter are temperature sensors for local display and remote transmission of electrical signals. The platinum resistance element is installed in the temperature measuring rod of bimetal thermometer, which can not only indicate the temperature on site, but also transmit the signals of thermocouple (resistance) and two-wire temperature transmitter. As a new generation of thermometer, wssp-411 bimetal thermometer with thermal resistance can be widely used in metallurgical, petrochemical, electric power, light textile, food and other industrial sectors.
specification
product application
Product characteristics
1Thermocouple (resistance), bimetallic thermometer or temperature transmitter
2The utility model has the advantages of small temperature measuring probe, high sensitivity, linear calibration, long life and so on.
3Suitable for working in harsh environment for a long time.
4The remote electrical signal has high accuracy and stable operation. It can also be output directly in the form of two-wire system to improve the anti-interference ability of the signal in the process of long distance transmission.
5, high ratio of performance to pric
Technical index
1, scope of measurement:-80~500℃
2, display accuracy level:1.5
3, deviation of remote electrical signal:
a.Semicolon:E(nickel-chromium-copper-nickel) allowable deviation ±2.5℃ or0.75% t
b.Semicolon:K(nickel-chromium-nickel-silicon) allowable deviation ±2.5℃ or0.75% t
c.Semicolon:Pt100(platinum resistance) allowable deviation:
A; ±(0.15+0.002t()
B; ±(0.30+0.005t()
d.Basic error with temperature transmitter: Δ=Δ1±0.5%FS
Δ1The basic output error is corresponding to the tolerance of thermocouple (resistance).
For the range of measurement
4~20mA)
Low working power supply voltage of transmitter12V,35VRated working voltage24V
Normal working environment:
a.Ambient temperature:-25℃ ~70℃
B.Relative humidity:5%~95%
c.f≤55HzAmplitude<0.15mm
d.There is no medium in the surrounding air that causes corrosion of the transmitter
Environmental temperature effects:≤0.05%/1℃
Model and specification
Type number |
Division number |
Temperature range ℃ |
Precision grade |
Protective pipe material |
Insertion length |
WSSE-401 |
E |
-120 -120 0-50 0-100 0-150 0-200 0-300 0-400 0-500 |
1.5 |
1Cr18Ni9Ti 304 316 316L Haas C ≤ 276 |
150 200 300 400 500 750 1000 1500 2000 Various sizes |
WSSE-501 |
|||||
WSSE-411 |
|||||
WSSE-511 |
|||||
WSSE-481 |
|||||
WSSE-581 |
|||||
WSSP-501 |
Pt100 |
||||
WSSP-411 |
|||||
WSSP-511 |
|||||
WSSP-481 |
|||||
WSSP-581 |
|||||
WSSXE-401 |
E |
||||
WSSXP-401 |
Pt100 |
||||
WSSXE-411 |
E |